Veinasa-Yw04 High Temperature Water Sensor Non-Contact Nitrogen Level Stainless Steel Ultrasonic Optical Liquid Level Sensor

Looking for high-quality, non-contact liquid level sensors? Look no further than Veinasa-Yw04. Our factory produces reliable, stainless steel ultrasonic sensors for measuring water and nitrogen levels.
Request a Quote

PRODUCTS DETAILS

  • Overview
  • Product Description
  • Product Parameters
  • Dimensional Drawing
  • Application Case
  • Company Profile
Overview

Basic Info.

Model NO.
Veinasa-YW04
Customized
Customized
Test Medium
Liquid Compatible with Materials
Measurement Range
0 ~ 100m
Accuracy
0.1%Fs, 0.25%Fs, 0.5%Fs
Stability
±0.25% F/S/Y, ±0.5% F/S/Y
Output Signal
4~20mA, 0~10V, RS485
Voltage
12~36V DC (Calibration: 24V 5%, Ripple < 1%)
Working Temperature
-20~80ºC
Overload Capacity
300%
Screw Joint
M20*1.5, G1/2, 1/2NPT, Other
Load Resistance
4 ~ 20mA
Transport Package
Covered with Carton Pack
Trademark
Veinasa
Origin
China

Packaging & Delivery

Package Size
25.00cm * 22.00cm * 20.00cm
Package Gross Weight
1.500kg

Product Description

Veinasa-Yw04 High Temperature Water Sensor Non-Contact Nitrogen Level Stainless Steel Ultrasonic Optical Liquid Level Sensor Veinasa-YW04 High Temperature Water Sensor Non-contact Nitrogen Level Stainless Steel Ultrasonic Optical Liquid Level Sensor
Product Description

 

Veinasa-Yw04 High Temperature Water Sensor Non-Contact Nitrogen Level Stainless Steel Ultrasonic Optical Liquid Level Sensor The liquid level transmitter adopts high-precision and high-sensitivity pressure sensitive elements,
converts the liquid level signals of the measured medium into standard analog signals or digital
signals through stable and reliable amplification circuits with strong anti-interference ability, and
has exquisite packaging technology and perfect detection technology to ensure the excellent
performance of the product, which is widely used in industrial automation fields such as petroleum,
chemical industry, metallurgy, environmental protection, metrology, automatic control engineering
and production process detection.
Product Parameters

 

Name
Parameters
Test medium
Liquid compatible with materials
Measurement Range
0 ~ 100m
Accuracy
0.1%FS, 0.25%FS, 0.5%FS
Stability
±0.25% f/s/y, ±0.5% f/s/y
Output signal
4~20mA, 0~10V, RS485
Voltage
12~36V DC (calibration: 24V 5%, ripple < 1%)
Power supply influence
less than 0.01%/V of output range
Working temperature
-20~80ºC
Compensation temperature
-20~80ºC
Temperature influence
1.55% fs/y, 3.0% fs/y
Overload capacity
300%
Screw joint
M20*1.5, G1/2, 1/2NPT, other
Load resistance
4 ~ 20mA
Veinasa-Yw04 High Temperature Water Sensor Non-Contact Nitrogen Level Stainless Steel Ultrasonic Optical Liquid Level Sensor
Dimensional Drawing

 

Veinasa-Yw04 High Temperature Water Sensor Non-Contact Nitrogen Level Stainless Steel Ultrasonic Optical Liquid Level Sensor Warning:

Never disassemble the transmitter without authorization!

It is forbidden to press the diaphragm of measuring element with fingers!

It is forbidden to insert any sharp object into the pressure-inducing hole!

 
Installation
1. Attention should be paid to transmitter before installation:
A. the static pressure generated by the liquid at the installation site shall not exceed the measuring range of the transmitter.
B. whether the measured liquid is compatible with the structural material of the transmitter.
C. whether the measured liquid will block the liquid inlet of the transmitter.

2. Put the probe part of the liquid level transmitter directly into the pool or other liquid containers. If there is sediment or
sludge at the bottom of the measured liquid, the measuring part should keep a certain distance from the sediment or
sludge to avoid being blocked.

3. When installing in still water, such as deep wells and pools, put the measuring part directly into the water for measurement,
and pay attention to the place far away from the inlet and outlet of the pump. If it is unavoidable, the method of inserting steel
pipes or PVC water supply pipes should be adopted. The inner diameter of the pipes is about 45mm, and several holes should
be made at different heights of the pipes (on the side away from the pump) so that water can enter the pipes smoothly.

4. Installation method in running water, as shown in the figure, is to insert a steel pipe into the waterway with an inner diameter
of about 45mm, and make several small holes at different heights on the opposite side of the water flow direction (pay attention
to fixing the steel pipe) to avoid unstable output signal when running water enters the pipe.
Veinasa-Yw04 High Temperature Water Sensor Non-Contact Nitrogen Level Stainless Steel Ultrasonic Optical Liquid Level Sensor Veinasa-Yw04 High Temperature Water Sensor Non-Contact Nitrogen Level Stainless Steel Ultrasonic Optical Liquid Level Sensor
Application Case

 

Veinasa-Yw04 High Temperature Water Sensor Non-Contact Nitrogen Level Stainless Steel Ultrasonic Optical Liquid Level Sensor
Company Profile

 

Veinasa-Yw04 High Temperature Water Sensor Non-Contact Nitrogen Level Stainless Steel Ultrasonic Optical Liquid Level Sensor Veinasa-Yw04 High Temperature Water Sensor Non-Contact Nitrogen Level Stainless Steel Ultrasonic Optical Liquid Level Sensor Veinasa-Yw04 High Temperature Water Sensor Non-Contact Nitrogen Level Stainless Steel Ultrasonic Optical Liquid Level Sensor Veinasa-Yw04 High Temperature Water Sensor Non-Contact Nitrogen Level Stainless Steel Ultrasonic Optical Liquid Level Sensor Veinasa-Yw04 High Temperature Water Sensor Non-Contact Nitrogen Level Stainless Steel Ultrasonic Optical Liquid Level Sensor

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours